Fuel conversion Kit 014919F Natural gas to propane
241647
156,106
156,106
Pool & Spa
Fuel conversion Kit 014919F Natural gas to propane
AVIA Flow Meter
100-10004418
264, 404
264, 404
Pool & Spa
Flow Meter
Electric SPA-PAK Heater
240362
552-2, 1102-2
ELS 552-2, ELS 1102-2
Pool & Spa
Installation and operating instructions for Electric SPA-PAK Heaters, specifically Models ELS 552-2 and ELS 1102-2, designed for pool and spa applications.
Pool Heater Vent Terminal Replacement Guide
240430
185, 265, 335, 405
185, 265, 335, 405
Pool & Spa
Guidelines for replacing vent terminals on specific pool heater models, including safety instructions and the detailed steps required for proper installation.
Spa Heater Pressure Switch Replacement Kit
240459
53B
53B
Pool & Spa
Instructions for replacing the pressure switch in spa heater model 53B, detailing the replacement process and adjustments needed for optimal operation.
Vent Terminal Installation Manual
240478
055B, 105A
055B/105A
Pool & Spa
Instructions focused on installing vent terminals for indoor and outdoor setups, ensuring proper mounting and securement for model 055.
Detailed instructions for converting gas types in various heater models, covering the replacement of main burner orifices, pilot orifice, and the pressure regulator assembly.
53, 55, 105, 151, GEMINI 181-401,
GEMINI/SPA PAK 183-403, VERSA 185-405, RP2100 185-405, PR185A-405A
DIGITAL GAS POOL HEATERS 206-407, BOILERS 133, 183-403, 202-402, 182-402, 181-401
Pool & Spa
Procedures for replacing the pilot burner assembly in various pool and spa heater models, including steps for disassembly, component replacement, and reassembly.
53, 55,105,151,153,155, GEMINI 181-401,GEMINI &
SPA PAK 183-403 VERSA 185-405, RP2100 185-405, P-R-185A405A C-R-185A-405A,
30-180 A & B, 133,183-403,202-402, 206-406,207-407,Pro Series R268A-R408A
Pool & Spa
Instructions for replacing the pilot orifice in a wide range of heater and boiler models, with specific steps for both standing and intermittent pilot systems.
This kit provides for replacement of the IID Gas Valve on the Raypak Pool and Spa Heaters listed.
High Limit Relocation Guide
240527
185A, 265A, 335A, 405A
185A, 265A, 335A, & 405A
Pool & Spa
Guide on relocating the high limit in the inlet/outlet header, including replacement of the header or complete heat exchanger if needed.
Millivolt Gas Conversions Guide
240544
B055
B055
Pool & Spa
Instructions for converting gas types between propane and natural, involving main burner orifices, pilot orifice, and the gas valve's pressure regulator assembly. It includes both Robertshaw and Honeywell gas control components.
Provides instructions for replacing the heat exchanger, including components like the flue collector and flange gaskets, specifically detailing steps for older Model 53 units.
All gas-fired models with S86 and S8600 ignition controls
Pool & Spa
Instructions for replacing the electronic ignition system, including parts such as the ignition control module and associated hardware.
Hot Surface Igniter Replacement Instructions
240563
30, 42, 66, 90, 135, 180
30, 42, 66, 90, 135, & 180
Pool & Spa
Provides the steps and components for replacing the hot surface igniter in specific models, ensuring proper alignment and functionality post-installation.
Solid State Thermostat PC Board Replacement Instructions
Guide for replacing thermostat PC boards in various heater models, including detailed installation steps and wiring diagrams
Millivolt Solid State Thermostat PC Board Replacement Instructions
240606
055A, 055B, 155A, 185B, 265B, 335B, 405B
055A, 055B, 155A, 185B, 265B, 335B, & 405B
Pool & Spa
Instructions for replacing the solid state thermostat control board in specified models, detailing the replacement process and necessary precautions
Fuse Replacement Kit for Analog Thermostat Control Board
240668
RP2100, R185, R265, R335, R405
R185 through R405 RP2100 IID Pool Heaters
Pool & Spa
This kit includes suitable replacement fuses for the analog thermostat control boards of RP2100 IID pool heaters, covering models R185 through R405.
Draft Hoods Field Installation for Pool Heaters
240671
RP2100, R185, R265, R335, R405
RP2100 Models 185 - 405
Pool & Spa
Instructions intended for qualified personnel for the field installation of draft hoods on RP2100 pool heater models ranging from 185 to 405.
Solid State Thermostat Replacement Instructions
240672
055, 105, 155, 185, 265, 335, 405
055, 105, 155, 185, 265, 335, & 405
Pool & Spa
Provides the necessary instructions and components for replacing the solid state thermostat control board and associated components for a range of models.
Millivolt Solid State Thermostat Replacement Instructions
240673
055A, 055B, 155A, 185B, 265B, 335B, 405B
055A, 055B, 155A, 185B, 265B, 335B, & 405B
Pool & Spa
Detailed instructions for replacing the solid state thermostat control board for specified millivolt models.
Millivolt Gas Conversion Propane to Natural
240674
130, 185, 206, 265, 266, 335, 336, 405, 406
130, 185, 206, 265, 266, 335, 336, 405, 406
Pool & Spa
This document provides instructions and components for converting specified millivolt heater models from propane to natural gas, ensuring a smooth transition and proper function after conversion.
Burner Tray Replacement
240677
RP2100, R185, R265, R335, R405
R185, R265, R335, & R405 RP2100 w/Standing Pilot
Pool & Spa
Instructions for replacing the burner tray on specific RP2100 models with a standing pilot.
This manual provides instructions for replacing the burner tray in RP2100 models with electronic ignition.
Field Installation of Heat Exchanger for Gas Booster Heater
240702
B-195
B-195
Pool & Spa
Provides instructions for the field installation of a heat exchanger on the B-195 model equipped with Hot Surface Ignition Systems.
Tube Bundle Installation for Gas Booster Heater
240703
B-195
B-195
Pool & Spa
Instructions for field installation of the tube bundle specifically for the B-195 Gas Booster Heater model.
Flue Collector Replacement for Gas Booster Heater
240704
B-195
B-195
Pool & Spa
Provides instructions for the field installation of the flue collector replacement kit for the B-195 model gas booster heater with hot surface ignition systems.
Combustion Chamber Top Installation for Gas Booster Heater
240705
B-195
B-195
Pool & Spa
Installation guide for the combustion chamber top on B-195 gas booster heaters with hot surface ignition systems.
MV Pilot Installation for Pool and Spa Heaters
240728
53, 53A, 53B, 055A, 055B, 151, 153, 153A, 155A
53, 53A, 53B, 055A, 055B, 151, 153, 153A, 155A
Pool & Spa
Instructions for installing the MV Pilot on various Raypak pool and spa heater models equipped with standing pilot millivolt systems.
RP2100 Pool and Spa Heaters 185-405, 206-407, 130, 106, 156
Pool & Spa
Provides detailed assembly directions for the replacement kits of the bypass spring, applicable to a range of RP2100 pool and spa heaters, ensuring proper operation and longevity of the units.
Instructions for the replacement of the Sensor Well Kit, specific to residential pool heaters equipped with polymer headers, including a step-by-step guide for service technicians.
Retainer Group Upgrade Kit Instructions
240751
RP2100, R185, R265, R335, R405
RP2100 Pool/Spa Heaters 185-405 with Polymer Headers
Pool & Spa
Instructions for installing the Retainer Group Upgrade Kit on RP2100 pool/spa heaters equipped with polymer headers.
Instructions for replacing O-rings in polymer headers to ensure a proper seal and prevent leaks in Raypak pool heaters. This kit is designed to accommodate all heaters with Polymer headers, helping to maintain the integrity of the heating system
Instructions for replacing the in/out header dam for polymer headers in specified Raypak pool heater models. It includes safety warnings and detailed steps for installation
This document outlines the replacement procedure for transformers in Raypak Pool & Spa heaters, detailing the process and necessary precautions to avoid electrical hazards
Instructions for replacing the Honeywell L4031A1156 dualstat and installing new pool control. Includes options for mounting in various locations within the heater's control areas, tailored for both small and large heater models. Details include control of the main pool supply loop and specific placement instructions.
Steps for replacing the polymer header baffle in specific pool heater models, ensuring proper assembly and function
Membrane Switch Decal Replacement
241331
RP2100, R185A, R265A, R335A, R405A
RP2100 Pool Heater Models R185A-R405A
Pool & Spa
Instructions for replacing the membrane switch decal on RP2100 pool heaters to ensure correct operation and interface interaction
High Limit Auto Reset Kit Installation
241389
55
055 Spa Heater
Pool & Spa
Provides parts and procedures for installing an auto-reset high limit thermostat in Model 055 spa heaters, including wiring modifications for IID units
Digital Gas Pool Heaters Models 185B, 206A, 207A, 265B, 266A, 267A, 335B, 336A, 337A, 405B, 406A, 407A
Pool & Spa
Instructions for replacing the PC control board and temperature sensor, integrating an ignition module and accommodating specific model adaptations, especially for propane setups
Step-by-step instructions for replacing or installing a new bezel cover on various digital gas pool heater models, with additional notes for models without tab slots
LCD Replacement for Digital PC Boards
241436
206A, 207A, 266A, 267A, 336A, 337A, 406A, 407A
Models with Advanced Flame Technology Control PCB
Pool & Spa
Procedures for replacing the LCD display module on digital PC boards using Advanced Flame Technology, detailing precautions and step-by-step instructions for safe installation
Control Board Replacement for Heat Pump Pool Heaters
Detailed instructions for replacing control boards in heat pump pool heaters, including steps for both like-model replacements and upgrades from non-digital boards
Instructions for safely replacing the fan blade in heat pump pool heaters to ensure proper operation and safety
Outdoor Vent Stack Kit Installation
241469
84 PROFESSIONAL, R259B, R409B
84 Professional Models 259 & 409
Pool & Spa
Provides components and instructions for installing a 6” outdoor vent stack on Professional 84 pool and spa heaters, detailing steps for proper assembly and safety precautions
Fan Capacitor Replacement Kit
241471
TWPH-2350EHT08, TWPH-2350EHT10, TWPH-2350EHT11
2350 Heat Pump Pool Heaters
Pool & Spa
Instructions for replacing the fan capacitor in model 2350 heat pump pool heaters, including steps for proper installation and safety precautions
Vent Adapter Kit for Category 1 Vent System
241487
84 PROFESSIONAL, R259, R409, R259B, R409B
84 Professional Pool & Spa Heaters
Pool & Spa
Provides a vent adapter and instructions for its installation on 84 Professional Pool and Spa Heaters, enhancing venting capabilities
84 Professional and X94 Professional Models 259, 409 & 410 Pool & Spa Heaters
Pool & Spa
Instructions for replacing the PC board on specified models, ensuring proper functioning of control systems
Air Pressure Switch Kit
241492
407, 407A, 407AL
Low NOx Model 407 Pool & Spa Heaters
Pool & Spa
Provides parts and procedures for replacing the air pressure switch in Model 407 Low NOx pool and spa heaters
Heat Pump Pool & Spa Heater
241496
5356, 6356, 6358, 8358
Model RA Series 5356, 6356, 6358 & 8358
Pool & Spa
Installation & Operating Instructions
Gas Valve Replacement Kits for IID Heaters
241524
106, 156, 106A, 156A
106 & 156
Pool & Spa
Directions for replacing gas valves in specified models, detailing steps for handling both natural gas and propane setups
Natural Gas to Propane Conversion Kit
241525
156, 156A
Model 156
Pool & Spa
Kit and instructions for converting from natural gas to propane, including replacement of pilot orifices and main burner orifices
Indoor Draft Hood & Outdoor High Wind Top Kit
241529
106, 156, 106A, 156A
106 & 156
Pool & Spa
Guide for installing indoor draft hoods and outdoor high wind tops for models 106 and 156, enhancing unit stability and performance under different conditions
Digital PC Board
241530
156, 156A
156 Above Ground Pool and Spa Heater
Pool & Spa
Provides a replacement kit for the digital thermostat PC board and sensor specifically designed for the model 156 above ground pool and spa heater, ensuring updated control and accurate temperature monitoring.
Solid State Thermostat PC Board Replacement Kit
241533
106, 106A
106
Pool & Spa
Provides a kit for replacing the analog thermostat PC board on model 106 heaters, ensuring proper control and operation
Replacement Potentiometer for Analog Temp Control
241536
130, 130A, 106, 106A
P-130 & 106
Pool & Spa
Instructions for the replacement Potentiometer for
Models P-130 and 106 Above Ground Pool and Spa Heaters.
Transformer Replacement Kit
241537
130, 130A, 106, 106A
Models P-130 & 106
Pool & Spa
Kit provides parts and instructions for replacing the transformer in specific models, ensuring electrical components operate safely and correctly
Provides all necessary components and instructions to replace polymer return headers on RP2100 heater models to maintain efficient operation and heat distribution
Instructions and specifications for installing Hurricane Tie Down Straps on various models of heat pump pool heaters. The manual details how to secure heaters against hurricane force winds, ensuring stability and safety during severe weather conditions.
Burner Tray Kit
241558
106A, 156A
Models 106A & 156A
Pool & Spa
Detailed steps for replacing the burner tray without a gas valve, including removal and installation instructions for maintaining or upgrading the heater's functionality
Complete Burner Tray Kit
241559
106A, 156A
Models 106A & 156A
Pool & Spa
Instructions for replacing the entire burner tray along with the gas valve, pilot, and bracket, aimed at restoring or enhancing the operational efficiency of the heaters
Burner Orifice Kit
241560
106A, 156A
Models 106A & 156A
Pool & Spa
Kit for replacing the main burner orifices on specific models, ensuring proper gas flow and combustion performance
Heat Exchanger Replacement Kit
241565
106, 156
Models 106 & 156
Pool & Spa
Provides all necessary parts and instructions for replacing the heat exchanger in specified models, including procedural steps for safe and effective installation
Return Header Replacement Kit
241566
106, 156
Models 106 & 156
Pool & Spa
Instructions for replacing the return header in specific pool and spa heater models, including detailed steps to ensure a secure and functional installation
Refractory Block Kit Installation
241576
X94, S-R410, SR410
X94 Model SR 410
Pool & Spa
Instructions for the installation of refractory block kits to maintain the integrity of the heater's structure and improve heat retention
O-Ring Gasket Kit Installation
241577
130A, 106A, 156A
Models P-130A, P/M 106, P/M 156
Pool & Spa
Directions for replacing O-Ring gaskets in specific pool and spa heater models to ensure a proper seal and prevent leaks
Models 106, P-130A, 156, RP2100 Models 185-405, 185A-405A, 206-406, 206A-406A, Professional Series 268A & 408A
Pool & Spa
Provides a replacement rollout switch, which is typically indicative of venting or heat exchanger issues, with detailed installation steps
Fuel Conversion Kit Installation
241579
X94, S-R410, SR410
X94 Professional Pool Heater Model 410
Pool & Spa
Instructions for converting fuel types from natural gas to propane or vice versa, ensuring correct gas orifice and adjustments for efficient operation
Blower and Blower Gasket Replacement
241585
X94, S-R410, SR410
X94 Professional Pool Heater Model 410
Pool & Spa
Provides parts and procedures for replacing the blower and gasket in specific models, with steps to ensure proper alignment and functionality
Blower Relay Kit Installation
241596
X94, S-R410, SR410
X94 Model 410
Pool & Spa
Instructions for installing a blower relay kit to maintain the operational efficiency of the blower system in the heater
Environmental Shield Kit Installation
241600
206, 266, 336, 406, 207, 267, 337, 407
Models 206-407
Pool & Spa
Guide to installing an environmental shield for the PC board to protect against moisture and debris, ensuring longer lifespan and stability of the controls
Instructions for replacing the digital PC board to update or repair the control system of the heater, including details on component handling and proper reassembly
L-100, L-100B, L-180-L-400, 105A & 105B, 153A, 155A, B & C, 181-401, 183-403A,
R185-R405B, 206-406A, 207-407A, C-315, X-94 MODEL 409
Pool & Spa
Kit for replacing the auto reset 135°F limit on several models, part of safety and regulation mechanisms
Tube Bundle Replacement Kit
241643
106, 156
Models 106 & 156
Pool & Spa
Instructions for replacing the tube bundles in specific pool and spa heaters, includes procedures for handling flue collector and tube sheet
Inlet-Outlet Header Replacement Kits
241644
106A, 130A, 156A
Models P/M 106A, P-130A & P/M 156A
Pool & Spa
Details on replacing the inlet-outlet headers, including steps for handling internal components and electrical connections
5K Temperature Sensor Replacement for Tropical Assembly Digital Board
241654
Not specified
Pool & Spa
Provides replacement 5K temperature sensors and instructions for retrofitting digital boards that default to 5K sensor values. The kit includes two sensors and insulation tape
Deliming Kit for S-R410 Heat Exchanger
241659
X94, S-R410, SR410
S-R410 (X94)
Pool & Spa
Instructions and parts for deliming the S-R410 heat exchanger, including PVC fittings and a tankless water heater descale kit to maintain efficiency
Kit includes springs and components to replace or repair bypass valves in specific heater models, enhancing flow regulation
Thermistor (Temperature Sensor) Kit for XTherm Indirect
241729
1005A, 1505A, 2005A
XTherm Indirect Pool Heaters Models 1005A-2005A
Pool & Spa
Replacement thermistors for monitoring water temperature in indirect pool heaters, including all necessary hardware for installation
High Limit 140° Kit
241730
1005, 1505, 2005, 1005A, 1505A, 2005A
XTherm & XTherm Indirect Pool Heaters Models 1005A-2005A
Pool & Spa
Kit to install or replace 140° high limit on specific XTherm models, providing critical safety and operational controls
XTherm Indirect Heat Exchanger Replacement
241731
1005A, 1505A, 2005A
XTherm Indirect Pool Heaters Models 1005A-2005A
Pool & Spa
Instructions for replacing the indirect heat exchanger in XTherm models, including details on handling and reinstallation procedures
Condensate Trap Kit for XTherm w/ Indirect
241737
1005A, 1505A, 2005A
XTherm H WH P 1005A-2005A & XTherm Indirect Pool Heaters Models 1005A-2005A
Pool & Spa
Provides components and instructions for replacing the condensate trap in specific XTherm indirect pool heaters
Titanium Heating Element Tube Assembly
241761
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters (5.5 kW for models 0005 & 0011, 9 kW for models 0018 & 0027)
Pool & Spa
Instructions for replacing the titanium heating element tube assemblies for different E3T model heaters, ensuring optimal heating performance
Thermistor Heating Chamber 27kW E3T
241762
27
E3T Series Electric Digital Pool & Spa Heaters (27 kW model only)
Pool & Spa
Guide for installing a replacement thermistor for the inlet or outlet in the 27 kW models, which helps in accurately measuring water temperature
E3T Inlet and Outlet Sensors
241763
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Instructions for replacing the inlet and outlet sensors on E3T series heaters, critical for monitoring water flow temperatures
PC Board Kits
241765
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Provides steps for replacing the PC boards with digital displays, ensuring the functionality and interface of the heater controls
Hall Effect Flow Sensor
241767
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Details the replacement of the Hall Effect flow sensor, which is essential for monitoring and managing the water flow through the heater
E3T Triac 3 Wire Kit
241768
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Instructions on replacing the 3-wire Triac, which is vital for controlling power flow and heating elements within the heater
Flow Sensor E3T
241769
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Provides the procedure for replacing the flow sensor in E3T series heaters, crucial for proper operation and safety
E3T O-Ring Kit
241770
5
E3T Series Electric Digital Pool & Spa Heaters (5.5 kW & 9 kW models)
Pool & Spa
Instructions for replacing the O-rings on the titanium heating element tube assemblies to prevent leaks and ensure efficient operation
240 Volt Transformer E3T
241772
0005, 0011
E3T Series Electric Digital Pool & Spa Heaters (0005 & 0011 kW models)
Pool & Spa
Guide for installing a new 240-volt transformer in specific E3T model heaters, ensuring proper electrical function and safety
E3T 1-1/2" & 2" Unions Replacement
241773
0005, 0011, 0018, 0027
E3T Series Electric Digital Pool & Spa Heaters
Pool & Spa
Instructions for replacing the 1-1/2” and 2” unions on E3T series heaters, including steps for safe disassembly and reassembly to maintain a secure water connection
All Raypak Pool Heaters with ProTek Shield Equipped Polymer Headers
Pool & Spa
Instructions for replacing inlet/outlet headers equipped with ProTek Shield on various Raypak pool heaters, including safety and installation steps
Water Flow Switch Replacement Instructions
241808
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Provides the necessary steps and parts to replace the water flow switch in various Heat Pump Pool Heater models, ensuring proper flow detection and safety
PC Board Replacement Instructions
241809
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Instructions for replacing the PC control board in specified Inverter model pool heaters, including detailed steps on handling electronic components safely
Power Filter Plate Replacement Instructions
241810
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Provides guidelines for installing a new power filter plate, ensuring effective filtration and electrical system protection
Touch Controller Replacement Instructions
241811
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Step-by-step instructions for replacing the touch controller in specific pool heater models, enhancing user interface and control
Inverter Board Replacement Instructions
241812
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Guide for replacing the inverter board in specific Heat Pump Pool Heaters, including precautions for handling electrical components
Fan Motor Replacement Instructions
241813
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Detailed procedure for replacing the fan motor, which is crucial for maintaining optimal airflow and cooling performance in the heater
Fan Blade Replacement Instructions
241814
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Instructions for replacing the fan blade to ensure efficient operation and air flow within the Heat Pump Pool Heater
Step-by-step guide to replacing the electronic expansion valve in various models, which is critical for refrigerant flow control in the cooling system
4-Way Valve Coil Replacement Instructions
241816
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Provides instructions for replacing the 4-way valve coil, essential for controlling the refrigerant direction flow in the heating and cooling cycles
Water Union Replacement Instructions
241817
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Directions for replacing water unions, ensuring secure and leak-free connections within the pool heating system
Water Union Gasket Replacement Instructions
241818
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Provides steps for replacing the water union gasket in specified models, including detailed instructions on handling the heat exchanger adapter and ensuring a proper seal to prevent leaks
Sensor Replacement Instructions
241819
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Instructions for replacing various sensors in the pool heaters, detailing how to access and replace sensors connected to the PC control board
Precision Inductor Replacement Instructions
241820
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Guide for replacing the precision inductor, which is critical for the operation of the heat pump pool heaters, including how to access and secure the sensor on the panel
Fuse Replacement Instructions
241821
30-I, 40-I, 50-I, 65-I
Models 30-I, 40-I, 50-I, 65-I
Pool & Spa
Provides the steps to replace the fuse on the power filter plate, ensuring safety measures are adhered to prevent electrical hazards
Installation Instructions for Condensate Drainage
241822
30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Models 30-I, 40-I, 50-I, 65-I, 40-O, 50-O, 65-O
Pool & Spa
Instructions for installing a condensate drain kit, detailing the components and steps involved in routing the drain hose properly to avoid water damage
Compressor Contactor Replacement Instructions
241824
40-O, 50-O, 65-O
Models 40-O, 50-O, 65-O
Pool & Spa
Steps for replacing the compressor contactor, including accessing the electrical components and ensuring proper connection
Compressor Capacitor Replacement Instructions
241825
40-O, 50-O, 65-O
Models 40-O, 50-O, 65-O
Pool & Spa
Guide for replacing the compressor capacitor, detailing how to safely remove and install the capacitor while ensuring all electrical connections are secure
Fan Motor Capacitor Replacement Instructions
241826
40-O, 50-O, 65-O
Models 40-O, 50-O, 65-O
Pool & Spa
Instructions for replacing the fan motor capacitor, which includes accessing the capacitor under the compressor capacitor and ensuring correct wiring
Transformer Replacement Instructions
241828
40-O, 50-O, 65-O
Models 40-O, 50-O, 65-O
Pool & Spa
Provides a detailed procedure for replacing the transformer in the specified pool heater models, including how to safely disconnect and reconnect electrical components
6-way Multiport Valve kit or a Union and Pressure gauge kit Replacement Instructions
241838
RPSF14, RPSF16, RPSF18, RPSF21, RPSF25, RPSF28
Protégé Series Sand Filters RPSF, RPSFP
Pool & Spa
Instructions for replacing the 6-way multiport valve and associated components like the pressure gauge and unions, ensuring correct installation and function
Clamp Lock with O-Ring Replacement Instructions
241839
RPSF14, RPSF16, RPSF18, RPSF21, RPSF25, RPSF28
Protégé Series Sand Filters RPSF, RPSFP
Pool & Spa
Instructions for replacing the clamp lock and O-ring on Protégé series sand filters, detailing the necessary steps for safe disassembly and reassembly to ensure proper sealing and filter operation
Laterals Replacement Instructions
241840
RPSF14, RPSF16, RPSF18, RPSF21, RPSF25, RPSF28
Protégé Series Sand Filters RPSF, RPSFP
Pool & Spa
Provides the necessary components and steps for replacing the lateral assembly in Protégé sand filters, including instructions for the removal and installation of the center pipe and manifold
Lock Ring, Clear Lid, O-Ring, and Basket Replacement Instructions
Protégé Series Pump and Filter RPAGP, RPSFP, RPCFP
Pool & Spa
Instructions for replacing the lock ring, clear lid, O-ring, and basket for Protégé pumps and filters, detailing the procedures to ensure proper assembly and leak prevention
Impeller, Seal and O-Ring Replacement Instructions
Protégé Series Pump and Filter RPAGP, RPSFP, RPCFP
Pool & Spa
Guide for replacing the impeller, mechanical seal, and O-ring in Protégé series pumps, including detailed instructions on handling and assembly to maintain optimal pump performance
Transparent Cover and Basket Replacement Instructions
241843
RPVSP1
Protégé Variable-Speed Pump (VSP) Model RPVSP
Pool & Spa
Procedures for replacing the transparent cover and pump basket on Protégé Variable-Speed Pumps, including tips on proper lid sealing and alignment for leak prevention
Diffuser, Impeller, and Seal Replacement Instructions
241844
RPVSP1
Protégé Variable-Speed Pump (VSP) Model RPVSP
Pool & Spa
Instructions for replacing the diffuser, impeller, and mechanical seal in Protégé VSP models, detailing the steps to dismantle and reassemble the pump components safely and efficiently
Programmable Controller Replacement Instructions
241845
RPVSP1
Protégé Series Variable-Speed Pump (VSP) Model RPVSP1
Pool & Spa
Guide for replacing the programmable controller PC boards on Protégé VSPs, emphasizing safety and accuracy in handling electronic components
Instructions for replacing the cartridge filter cover on Protégé cartridge filter pumps, including steps for proper lid removal, O-ring lubrication, and reassembly to ensure a secure fit
Mounting Hardware and Cartridge Filter Base Replacement Instructions
Provides the necessary hardware and steps for replacing the mounting base and hardware for Protégé cartridge filters, ensuring stability and secure installation
PC Board Replacement Instructions
241857
30-O, 40-O
30-O, 40-O
Pool & Spa
Instructions for replacing the PC board in Crosswind side discharge heat pump pool heaters, detailing the procedures for safe electrical disconnection and board installation
Sensor Kit Replacement Instructions
241858
40-O, 50-O, 65-O
40-O, 50-O, 65-O
Pool & Spa
Instructions for replacing the on-off sensors for specified heat pump models, ensuring proper operation and safety measures
ProTek Shield Retrofit Installation Instructions
241888
206, 266, 336, 406, 207, 267, 337, 407, 106, 156
Various Raypak Polymer and ASME Header Pool Heaters
Pool & Spa
Provides components and instructions to retrofit ProTek Shields on heaters to protect against corrosive environments and extend heater life
Water Chemistry Installation Instructions
241907
AVIA, 264, 404, 264A, 404A
AVIA Series
Pool & Spa
Instructions on how to install and maintain proper water chemistry for AVIA series pool heaters to ensure optimal operation and longevity .
Spider Gasket for 6-Way Multiport Valve Replacement
241908
RPSF14, RPSF16, RPSF18, RPSF21, RPSF25, RPSF28
Protégé Series Sand Filters, Models RPSF & RPSFP
Pool & Spa
This manual provides instructions for replacing the spider gasket in the 6-way multiport valve on the Protégé series sand filters.
This kit provides instructions and components to prevent water intrusion into the digital control board of specified heat pump pool heater models. It is designed to enhance the durability and operational reliability of the heaters by protecting sensitive electronic components.
Header O-Ring Gaskets Replacement
241951
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Provides detailed procedures for replacing the O-ring gaskets to ensure a proper seal and prevent leaks in AVIA heaters
Transformer Replacement Instructions
241952
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guidelines for safely replacing the transformer to maintain electrical system integrity in AVIA pool and spa heaters
Vent, Air & Differential Pressure Switch Replacement
241963
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the air pressure switch which monitors and controls air pressure within the heater for safe operation
Sensor Adaptor Replacement
241964
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Provides the procedures for replacing the sensor adapters that hold the temperature sensors, critical for accurate temperature measurement
195° Limit Switch Replacement
241965
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Detailed instructions for replacing the limit switch in AVIA heaters to ensure efficient operation and safety
Blower Replacement
241968
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Detailed instructions for replacing the blower in AVIA heaters to ensure efficient operation and safety
PC Board Replacement
241969
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guide for replacing the PC board to ensure the electronic control of the heater operates correctly
Bezel Cover Replacement
241970
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the Bezel Cover, including steps to ensure safety and correct installation
Water Pressure Switch Replacement
241971
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Detailed procedure for replacing the Water Pressure Switch to ensure proper operation and safety of the heaters
Return Header Replacement
241972
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the return header, including steps for removing old components and installing new ones
Inlet/Outlet Header Replacement
241973
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guide for replacing the polymer inlet/outlet header, detailing component removal and installation procedures
Outlet Adapter Replacement
241975
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Steps to replace the outlet adapter, ensuring the correct assembly and functioning of the heating unit
Deliming Kit with 5/8" Finned Tubing
241978
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Deliming instructions for cleaning heater tubes to remove scale buildup and maintain efficiency
Drain Plug Replacement
241979
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the drain plugs in the inlet/outlet and return headers to prevent leaks and ensure proper drainage
Bypass Valve & Bypass Dam Replacement
241980
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Procedure for replacing the bypass valve and dam to manage flow rates and prevent calcification in the tubes
Unitherm Governor Installation
241981
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for installing the Unitherm Governor, which regulates water temperature within the heater
Gas Valve Replacement
241982
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Detailed steps for replacing the gas valve to ensure proper gas flow and operation of the heater
LCD Display Board Replacement Instructions
241983
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Provides steps for replacing the LCD display board in AVIA heaters, including precautions for electrical safety and ensuring proper display function
Gas Orifice Replacement Instructions
241993
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions on replacing the gas orifice for different fuel types, detailing the process to ensure correct fuel delivery and combustion efficiency
Tube Dampener Coil Installation Instructions
241994
206, 266, 336, 406, 207, 267, 337, 407, 268, 408
Models 206-408
Pool & Spa
Instructions on installing tube dampener coils in pool heaters to stabilize and protect the heat exchanger from thermal and mechanical stresses
Adjustable Outdoor Base Installation Instructions (Canada Only)
242035
106, 156
Atmospheric Above-Ground Pool & Spa Heaters Models 106-156
Pool & Spa
Guide for installing adjustable outdoor bases for specified models in Canada, enhancing stability and performance
Adjustable Outdoor Base Assembly Instructions
242074
206A, 266A, 336A, 406A
Above-Ground Atmospheric Pool Heaters Models 206A-406A
Pool & Spa
Provides steps for assembling and installing outdoor bases for larger pool heaters, ensuring proper installation and support
High Elevation Propane Kit Installation Instructions
242076
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guidelines for installing a high elevation propane kit in AVIA heaters, essential for operations at high altitudes, ensuring proper functioning and safety
Instructions for upgrading from a 40 amp to a 50 amp contactor in Raypak heat pump pool and spa heaters. This document guides technicians through the replacement process to ensure proper handling and installation for enhanced electrical capacity and reliability.
Header O-Ring Gaskets Replacement
100-10000185
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the O-Ring gaskets in the heater to ensure proper sealing and prevent leaks
Blower Replacement
100-10000186
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guidelines for replacing the blower in AVIA heaters, detailing steps to ensure safe removal and installation of new blower units
Outlet Adapter Replacement
100-10000187
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Procedures for replacing the outlet adapter to maintain the integrity and functionality of the water flow system
Instructions for replacing the bezel cover on Crosswind V models 4550-8550, essential for protecting the heater's control interface from external elements
Directions for replacing the PC board display which includes a detailed procedure to access and install the new interface component in Crosswind V models 4550-8550
Replacement of Heating Element for E3T 3-Phase
100-10000335
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Provides instructions for replacing various heating elements, detailing the specific models and power ratings applicable, ensuring proper operation and safety
Fuse and Fuse Holder Replacement Instructions
100-10000336
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Details the steps to replace fuses and fuse holders for different voltage specifications, ensuring safe and proper electrical function
Front Panel, Door Assembly & Upper Cabinet Support Replacement Instructions
100-10000337
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Instructions on how to replace the front panel, door assembly, and upper cabinet support, including details on handling and installation
PC Board Display and Mounting Replacement
100-10000338
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Guides through the process of replacing the PC board display and support structure, ensuring correct reassembly for operational stability
Solid State Relay Replacement Instructions
100-10000339
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Procedures for replacing the solid-state relay, which includes details on different relay sizes based on kW ratings of the unit
Manual Reset Switch and Button Replacement
100-10000340
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Provides instructions for replacing the manual reset switch and button, detailing the assembly and electrical connections necessary for safe operation
Inlet and Outlet Temp Sensor Replacement Instructions
100-10000341
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Step-by-step guide for replacing temperature sensors at the inlet and outlet, crucial for accurate temperature monitoring
Flow Sensor Replacement Instructions
100-10000342
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Details the replacement of the flow sensor switch, essential for proper water flow detection and heater operation
Transformer Replacement Instructions
100-10000343
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Instructions for replacing 208V and 480V transformers, ensuring the electrical system functions correctly with detailed guidance on handling and safety
Contactor Replacement Instructions
100-10000344
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T 3-Phase Electric Commercial Pool & Spa Heaters
Pool & Spa
Guide for replacing the 208V and 480V contactors, including steps for safe disconnection and installation of new units
Temperature Vent Sensor Replacement
100-10000540
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Step-by-step instructions for replacing the temperature sensor vent to ensure accurate temperature readings and heater safety
Inlet Header Adapter Replacement
100-10000541
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Details on replacing the inlet header adapter, vital for maintaining proper connection and seal at the water inlet
Combustion Chamber Brackets Replacement
100-10000542
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing combustion chamber brackets and seals to ensure efficient operation and safety of the heater
Auto Reset Thermostat Switch Replacement
100-10000543
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guides the replacement of the auto-reset thermostat switches, crucial for maintaining safe operating temperatures
Burner Replacement
100-10000544
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Provides steps to replace the burner unit, ensuring the heater operates efficiently and safely
Wire Harness Replacement
100-10000545
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Detailed procedures for replacing various wire harnesses in the heater to maintain electrical system integrity
Pressure Relief Valve (PRV) Line Installation
100-10000546
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for installing the pressure relief valve line, an optional safety feature for managing pressure within the heater
Refractory Replacement Instructions
100-10000547
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Provides detailed instructions for replacing the refractory components in AVIA heaters, including safety precautions, necessary tools, and step-by-step procedures for disassembly and reassembly
Tube Bundle Replacement Instructions
100-10000548
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Guides the replacement of the tube bundle in AVIA heaters, detailing the parts involved, tools required, and sequential steps to ensure proper installation and function
Heat Exchanger Replacement Instructions
100-10000549
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for replacing the heat exchanger in AVIA pool and spa heaters, including descriptions of components, tool requirements, and detailed procedural steps
Quick start guide for using the Raymote app with Crosswind V heaters, detailing app setup and troubleshooting for remote control functionality
Manual Reset Limit Replacement
100-10000824
18, 24, 30, 45, 54, 0018, 0024, 0030, 0045, 0054
E3T Series Electric Digital Pool & Spa Heaters (Models: ELS 0005 through ELS 0027)
Pool & Spa
Provides instructions for replacing manual-reset limits designed to prevent overheating by shutting down the heater when temperature exceeds safe limits. Different models have varying numbers of limits based on their kW rating
Tube Coil Dampeners Installation
100-10001065
AVIA, 264, 404, 264A, 404A
AVIA
Pool & Spa
Provides instructions for installing tube dampener coils in AVIA heaters, aimed at improving efficiency and reducing operational stress. Details include parts list, necessary tools, and installation steps
84 Series Professional Heaters (Models: 259 & 409) X94 Professional Heaters (Model: 410)
Pool & Spa
This kit offers detailed instructions for replacing the PC Board in Raypak 84 Professional Pool and Spa Heaters, including Models 259 & 409, as well as the X94 Professional Heater (Model 410).
High Limit Manual-Reset Replacement
100-10001151
0005, 0011, 0018, 0024
E3T Electric Pool & Spa Heaters
Pool & Spa
Detailed instructions for replacing the high limit manual-reset switch which acts as a safety device to shut off power to the heater to prevent overheating
Transformer Replacement
100-10001152
0005, 0011, 0018, 0024
E3T Electric Commercial Pool & Spa Heaters (Models: ELS 0005 through ELS 0027)
Pool & Spa
Instructions for replacing the transformer necessary for converting incoming electrical voltage to levels suitable for the heater's operation
Thermistor Replacement
100-10001153
0005, 0011, 0018, 0024
E3T Electric Commercial Pool & Spa Heaters
Pool & Spa
Guide on how to replace inlet and outlet thermistors that monitor water temperature, crucial for the heater's efficient operation
Terminal Block Replacement
100-10001154
0005, 0011, 0018, 0024
E3T Electric Commercial Pool & Spa Heaters
Pool & Spa
Instructions for replacing the terminal block, which connects various electrical components within the heater
Push Button Replacement
100-10001155
0005, 0011, 0018, 0024
E3T Electric Commercial Pool & Spa Heaters
Pool & Spa
Steps for replacing the push button assembly used to manually reset or test the heater's functions
Relay PCB Replacement
100-10001156
0005, 0011, 0018, 0024
E3T Electric Commercial Pool & Spa Heaters
Pool & Spa
Provides procedures for replacing the relay printed circuit board (PCB), which controls the electrical pathways within the heater
Tube Bundle Insert Installation Instructions
100-10001240
AVIA, 264, 404, 264A, 404A
264A, 404A
Pool & Spa
Instructions for the installation of tube bundle inserts on AVIA heaters, detailing the tools required, step-by-step installation procedures, and safety warnings
Installation instructions for the External Water Bypass Kit, designed to manage water flow and enhance operational efficiency in Crosswind V models 4550-8550
Remote Control Panel REC08 Installation
208873
85, 120
XPak Ninety Plus 85 & 120
Boilers & Water Heaters
Provides instructions for installing the REC08 Remote Control Panel for XPak Ninety Plus models 85 and 120.
Indoor Draft Hood & Outdoor Stackless Top Installation Instructions
240476
130, 133, 155
130, 133 & 155
Boilers & Water Heaters
Instruction sheet for the installation of indoor draft hoods and outdoor stackless tops for models 130, 133, and 155.
All Commercial Model Heaters with L4031C and L4031A Controllers
Boilers & Water Heaters
Provides instructions for replacing the Honeywell L4031A1156 dual-stat in commercial model heaters. The document outlines steps to replace the dual controller, which includes both an auto reset tank stat and a manual reset high limit controller, with individual auto and manual reset controls.
Outdoor Stack Installation Instructions
240535
130, 155
130 & 155
Boilers & Water Heaters
Instructions for the installation of outdoor stacks specifically designed for models 130 and 155.
Burner Tray Replacement
240566
155A, 185B, 265B, 335B, 405B
155A, 185B, 265B, 335B, & 405B
Boilers & Water Heaters
Guide on replacing the burner tray assembly which includes the gas valve and pilot, detailing specific steps for both Honeywell and Robertshaw valves.
Burner Tray Replacement
240566
155A, 185B, 265B, 335B, 405B
155A, 185B, 265B, 335B, & 405B
Boilers & Water Heaters
Instructions for replacing the burner tray with electronic ignition, including the gas valve and pilot, detailed steps for installation and testing for proper function
Burner Tray with Electronic Ignition Replacement
240567
155A, 185B, 265B, 335B, 405B
Models 155A, 185B, 265B, 335B & 405B
Boilers & Water Heaters
This kit offers suitable replacements for the listed model numbers, featuring burner trays with electronic ignition.
Commercial Type W Water Heaters 133-4001, ADB 500-1000, Hi-Delta 302-2340
Boilers & Water Heaters
Instructions for field installation of the B9 Two Stage Temperature Controller specifically designed for domestic hot water applications on Raypak commercial type W water heaters, including model ranges 133-4001, ADB 500-1000, and Hi-Delta 302-2340. The guide is intended for units that require precise temperature control management.
Installation instructions for the Low Profile "Pagoda" outdoor top. These heater tops, designed for commercial and low NOx models, are intended for indoor use but can be adapted for outdoor installation.
Installation Location of Temperature and Pressure Gauge
Installation instructions for Gas Pressure Switch kits (S-1 and S-2) for various models of Hi Delta heaters, boilers, and Delta Ltd units.
Field Installation of Draft Hoods for Commercial Boilers
241104
182, 260, 330, 400, 181, 261, 331, 401
182, 260, 330, 400 and Low NOx 181, 261, 331, 401
Boilers & Water Heaters
Provides instructions for installing draft hoods on commercial boilers, including models 182, 260, 330, 400 and Low NOx variants 181, 261, 331, 401. The guide details an improved installation method that utilizes an adapter plate, allowing for the draft hood installation without the need to remove the top of the heater.
Installation Instructions for Flow Switch Option F-1
Provides detailed wiring instructions for transitioning from a Robertshaw to a Honeywell gas valve. This document addresses the necessary changes to accommodate the new valve, ensuring that the wiring aligns correctly with the updated components.
Fuse and Fuse Holder Installation
241126
500, 750, 1000, 1500
ADB 500, 750, 1000, & 1500
Boilers & Water Heaters
Instructions for the installation of fuses and fuse holders specifically for ADB models ranging from 500 to 1500.
Pump Override Installation Instructions
241138
Unspecified
Boilers and Water Heaters
Installation sheet for adding a pump override feature.
Hi Delta SureRack Kit
241142
122, 162, 202, 242, 322
122-322
Boilers and Water Heaters
Provides instructions for the installation of the Hi Delta SureRack Kit designed for models 122 through 322
Outlines the process for the installation of the Delta Limited Outdoor Vent Kit suitable for models 399 through 2339
PC Board, Temperature Control & Sensor Replacement
241169
185A, 265A, 335A, 405A
185A, 265A, 335A, & 405A
Boilers & Water Heaters
PC board with integrated ignition module and 3-wire temperature sensor for specific models. Includes information on a gasket and plastic shield to protect against moisture accumulation.
CHX Rack Assembly Instructions
241174
402, 502, 652, 752, 902
Hi Delta Models 402, 502, 652, 752, 902
Boilers & Water Heaters
Instruction sheet for the assembly of CHX rack intended for use with specified Hi Delta models.
CHX Rack Assembly Instructions
241175
992, 1262, 1532, 1802, 2002
Hi Delta Models 992, 1262, 1532, 1802, 2002
Boilers & Water Heaters
Instruction sheet for the assembly of CHX rack intended for use with specified Hi Delta models.
HI DELTA Tube Bundle & Heat Exchanger Support Brackets
Instructions for replacing the tube bundle assembly using heat exchanger support brackets to maintain stability of the upper flue collector during disassembly and reassembly .
Provides instructions for the installation of the replacement air pressure switch, also known as the fan proving switch, for specific Hi-Delta models.
Air and Water Sensors Installation for Y-200 Series Electronic Boiler Sequencer & Outdoor Reset Control System
241284
Y-200, Y-241, Y-281, Y-306
Hydronic Heating Applications / Domestic Hot Water Supply Applications
Boilers & Water Heaters
Instructions for the proper installation of air and water temperature sensors for use with the Y-200 series control system, detailing specifications for sensor placement and wiring for both hydronic heating and domestic hot water supply systems
(2 Stage) H Models: 0030A/B, 0042A/B, 0066A/B, 0090A/B, 0135A/B, 0180A/B
Boilers & Water Heaters
Replacement for the gas valve in the specified 2-stage H model residential boilers.
Air Vent Kit (Option A-30) Installation
241314
503A, 753A, 1003A, 1253A, 1503A, 1753A, 2003A
MVB 503–2003
Boilers & Water Heaters
The installation instructions are for the Air Vent Kit, designed to assist in air elimination in hydronic systems, particularly for vertical boilers like the MVB series.
This kit contains all necessary components for replacing the blower in specified MVB boiler and water heater models, ensuring optimal operation and efficiency.
Manual for installing a recess box specifically designed for outdoor installation of tankless water heaters. Compatible with a wide range of models, including standard and low NOx versions, to ensure secure and protected installation.
Tankless Water Heater Pipe Cover Assembly Installation Instructions
Manual providing installation instructions for the pipe cover assembly for various models of tankless water heaters.
Outdoor Vent Termination Kit Installation
241375
300, 500, 850
XFyre 300-850
Boilers & Water Heaters
Instructions for installing the outdoor/vent termination kit for XFyre models 300 to 850, detailing the assembly of the flue exhaust adapter and vent termination tee.
DHW Pump Relay Assembly Kit Installation
241383
85, 120
Models XPak 85 and 120
Boilers & Water Heaters
Instructions for the installation of the DHW Pump Relay Assembly Kit in XPak models 85 and 120.
Installation instructions for the 651678 adapter board, enabling Raytherm commercial boilers and water heaters to use a 4-20 mA signal for controlling the Honeywell V-9055 motorized actuator.
Hi Delta Models 302B-2342B, Delta Ltd Models 399B-2339B
Boilers & Water Heaters
Installation instructions for the B-60 control option, which allows Hi Delta and Delta Limited units to accept external 0-10 VDC or 0-20mA modulating signals for stage closure.
Instructions for assembling and installing a pipe cover for tankless water heaters, suitable for a variety of models. This cover ensures the piping associated with the heater is neatly concealed and protected from external elements.
This manual provides basic instructions for the proper installation of a recess box for various models of tankless water heaters. It is intended for installers with fundamental carpentry skills and plumbing knowledge.
Tankless Water Heater Pipe Cover Assembly Installation Instructions
This manual provides instructions for installing the pipe cover assembly on various models of tankless water heaters. It is designed for installers with basic carpentry and plumbing skills, emphasizing the need to follow all applicable local building, electrical, and plumbing codes.
Manual providing basic installation instructions for the recess box for a range of tankless water heaters. Intended for installers with fundamental carpentry and plumbing skills, the manual also notes the importance of complying with local building, electrical, and plumbing codes.
Stage Controller Internal Field Mounting Instructions
Instructions for installing a recess box designed for a variety of tankless water heater models. The guide is for installers with basic construction and plumbing expertise, and it emphasizes the necessity of adhering to all applicable local codes.
Polypropylene Vent Adapter Kit
241501
1005, 1505, 2005
XTherm Models 1005-2005
Boilers & Water Heaters
Instructions for installing the Polypropylene Vent Adapter Kit on XTherm models 1005-2005.
Xpak FT Wall Hung Heating Boiler Flow Switch Kits
241572
88AR, 108AR, 198AR, 278AR, 398A
Xpak Models 88A-398A
Boilers & Water Heaters
The kits assist in the initial installation or replacement of the flow switch for Xpak FT.
LO & HI Gas Pressure Switch Kit
241573
88AR, 108AR, 198AR, 278AR, 398A
Xpak FT Boilers Only
Boilers & Water Heaters
This kit provides the components and instructions needed to replace the low and high gas pressure switches.
Manual Reset Low Water Cut-Off (LWCO)
241574
88AR, 108AR, 198AR, 278AR, 398A
Xpak FT Boilers Only
Boilers & Water Heaters
The kit provides parts and instructions for the installation of a manual reset low water cut-off for the Xpak FT boilers.
XPak FT Alarm Buzzer Kit E5 Alarm
241575
88AR, 108AR, 198AR, 278AR, 398A
Xpak FT
Boilers & Water Heaters
This kit offers components for installing the E5 Alarm Buzzer for the XPak FT's alarm system.
Gas Valve Replacement Kit
241586
88A, 108A
XPak FT Wall Hung Heating Boiler Models 88A & 108A
Boilers & Water Heaters
The manual details the procedure for replacing the gas valve assembly kit specifically for the XPak FT Models 88A and 108A, ensuring proper maintenance and function of the heating system.
Gas Valve & Blower Assembly Kits
241587
88A, 108A
XPak FT Wall Hung Heating Boiler Models 88A & 108A
Boilers & Water Heaters
Instructions are provided for replacing the gas valve and blower assembly kit for the XPak FT Models 88A and 108A, which are crucial for the heater's optimal performance and safety.
LCD Window Gasket Kit
241588
88AR, 108AR, 198AR, 278AR, 398A
XPak FT Wall Hung Heating Boiler Models 88AR-398A
Boilers & Water Heaters
This manual includes instructions for the replacement of the LCD panel gasket applicable to all sizes of the XPak FT models. The gasket ensures the integrity and protection of the LCD panel from environmental factors.
Low Water Cut-Off Component Kits
241589
88AR, 108AR, 198AR, 278AR, 398A
XPak FT Models 88A-398A
Boilers & Water Heaters
Describes the components and installation process for low water cut-off kits used in XPak FT heating boilers.
Vent Temperature Limit Switch
241590
88AR, 108AR, 198AR, 278AR, 398A
XPak FT Models 88A-398A
Boilers & Water Heaters
Outlines the replacement of the vent temperature limit switch in XPAK FT models to prevent overheating and ensure safety.
Barbed Hose Fitting Kit
241592
300A, 400A, 500A, 700A, 850A
XFyre Models WH & H300A – WH & H850A
Boilers & Water Heaters
The kit provides for the replacement of the barbed fitting for the XFyre Model Sizes 300A- 850A.
Blocked Vent Switch Kit
241594
88AR, 108AR, 198AR, 278AR, 398A
XPak FT Wall Hung Heating Boiler 88A-398A
Boilers & Water Heaters
This kit provides for replacement of the Blocked Vent Switch for the XPak FT Model 88A - 398A.
PIM Weather Shield Kit
241599
300A, 400A, 500A, 700A, 850A
XFyre Models H WH 300A-850A
Boilers & Water Heaters
Installation or replacement of the weather shield on XFyre models 300A-850A
Combustion Blower Universal Replacement Kit
241619
HD101, HD151, HD251, HD301, HD401
Hi Delta SS Heaters
Boilers & Water Heaters
This manual provides instructions for the replacement of the combustion blower on Hi Delta SS heaters.
Instructions for the quick setup and basic operations of the touchscreen interface.
Temperature Control Limit
241636
300A, 400A, 500A, 700A, 850A
XFyre Models 300, 300A, 400, 400A, 500 & 500A
Boilers & Water Heaters
This kit provides instructions for the field installation of the manual reset temperature limit for XFyre appliances listed above.
Air Filter Access for Hi-Delta SS
241645
HD101, HD151, HD251, HD301, HD401
Models HD101, HD151, HD251, HD301 & HD401
Boilers & Water Heaters
This manual provides instructions for accessing the air filter on Hi-Delta SS models HD101, HD151, HD251, HD301, and HD401.
D-32 PVC Adapter 6" or 8"
241646
1005A, 1505A, 2005A
Xtherm 1005A, 1505A & 2005A
Boilers & Water Heaters
These instructions cover the field replacement of the D-32 PVC 6" or 8" vent adapter. The 6" adapter is only for installation on the XTherm model 1005A, and the 8" adapter is for the XTherm models 1505A and 2005A.
XVERS L Models 406L-856L & XFiire Models 300B-1000B
Boilers & Water Heaters
This kit enables a field retrofit of the Flow Meter and Flow Meter Manifold for Raypak Commercial Boilers of the XVers L Models 406L-856L & XFiire Models 300B-1000B.
E5 Alarm with 4” Bell Kit & E15 Alarm Buzzer Kit Installation
XVers L Models: 406L-856L & XFiire Models: 300B - 1000B
Boilers & Water Heaters
The kit provides for a field retrofit of the E5 Alarm with 4” Bell and E15 Alarm Buzzer on Raypak Commercial Boilers of the XVers L Series (Models: 406L- 856L) and XFiire Models (300B - 1000B).
Cabinet Limit Kit
241798
0856, 1006, 1256, 1506, 1756, 2006, 2506, 3006
XVers Models 856-3006
Boilers & Water Heaters
The kit provides for a field retrofit of the Cabinet High Limit for Raypak Commercial Boilers of the XVers series, Models 856-3006.
This manual details how to retrofit an LCD display and UDB board on Hi Delta and MVB units, providing the necessary parts and instructions for units not originally equipped with these features.
This manual provides instructions for enabling the Raymote feature on XFiire heaters, detailing the installation of the necessary SD card software.
Gas Conversion Kit
241890
300B, 400B, 500B, 650B, 800B, 1000B
XFIIRE 300B-1000B & IFire 300-1000
Boilers & Water Heaters
This manual provides instructions for converting the fuel source on XFiire and IFire models from natural gas to propane
XVERS L Fuel Change Kit
241891
406L, 506L, 606L, 726L, 856L
Xvers L 406L-856L
Boilers & Water Heaters
This kit enables the conversion of fuel source on XVERS L models from a factory preset fuel to another fuel type, specifically from natural gas to propane.
XVERS Fuel Change Kit
241895
0856, 1006, 1256, 1506, 1756, 2006, 2506, 3006
Xvers 0856 - 3006
Boilers & Water Heaters
This kit facilitates the conversion of an XVers boiler's operation from one fuel type to another, specifically from natural gas to propane, or from propane to natural gas.
Hot Surface Igniter Replacement Kit
241986
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This kit provides instructions for replacing the Hot Surface Igniter (HSI) specifically designed for XVers boilers powered by KOR.
Burner Assembly Replacement Kits
241987
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the burner assembly specifically designed for XVers boilers powered by KOR.
Air Filter Replacement Kits
241988
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the air filter specifically designed for XVers boilers powered by KOR.
Burner Access Plate Replacement Kit
241989
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the burner access plate specifically designed for XVers boilers powered by KOR.
Control Box Replacement Kit
241990
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the control box specifically designed for XVers boilers powered by KOR.
Power Supply Box Replacement Kit
241991
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the power supply box specifically designed for XVers boilers powered by KOR.
Refractory Replacement Kit
241992
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the refractory assembly specifically designed for XVers boilers powered by KOR.
Burner Access Gasket Replacement Kits
241995
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the burner access gasket specifically designed for XVers boilers powered by KOR.
Burner Gasket Replacement Kits
241996
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the burner gasket specifically designed for XVers boilers powered by KOR.
Burner Assembly Replacement Kit
241997
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the burner assembly specifically designed for XVers boilers powered by KOR.
Flame Sensor Gasket Replacement Kit
241998
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the flame sensor gasket specifically designed for XVers boilers powered by KOR.
Flame Sensor Probe Replacement Kit
241999
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This kit contains components for installing the flame sensor probe on XVers boilers powered by KOR, providing detailed instructions for the installation process.
Hot Surface Igniter Gasket Replacement Kit
242000
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This kit includes instructions for replacing the igniter gasket on XVers boilers powered by KOR, ensuring proper installation and function.
Gas Conversion Kit
242003
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This kit facilitates the conversion of XVers boilers powered by KOR from natural gas to propane, or from propane to natural gas, providing flexibility in fuel source options.
CSD-1 Field Upgrade Kit High and Low Gas Pressure Switches
242007
406L, 506L, 606L, 726L, 856L
XVers L Heating Boiler, Models 406L-856L
Boilers & Water Heaters
This kit enables a field upgrade to CSD-1 standards, incorporating high and low gas pressure switches for Raypak Commercial Boiler models of the XVers L series, specifically for Models 406L-856L.
Stainless Steel Door Replacement Kit
242010
300B, 400B, 500B, 650B, 800B, 1000B
XFIIRE Boilers: H7 300B-1000B XFIIRE Water Heaters: WH7 300B-1000B IFIRE Boilers: IGBWSF1 0300-1000 IFIRE Water Heaters: IVGWSF1 0300-1000
Boilers & Water Heaters
These instructions provide direction for the field installation of the stainless steel heat exchanger door on all models of XFIIRE/IFIRE units.
Sight Glass Replacement Kit for MVB Water Heater/Boiler
This manual provides instructions for installing the sight glass replacement kit on MVB water heaters and boilers.
Auto Temp Limit Replacement Kit
242038
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This kit includes instructions for replacing the Auto Temp Limit specifically designed for XVers boilers powered by KOR, covering models 1007-4007.
Filter Box and Gasket Replacement Kit
242039
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing both the Filter Box and Gasket specifically designed for XVers boilers powered by KOR, covering models 1007-4007.
Sediment Trap and Gas Flange Gasket Replacement Kit
242040
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing both the Sediment Trap and Gas Flange Gasket specifically designed for XVers boilers powered by KOR, covering models 1007-4007.
PC Board VERSA IC Replacement Kit and PIM Multi-Try Kit
242041
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
This document provides instructions for replacing the PC Board VERSA IC and installing the PIM Multi-Try Kit specifically designed for XVers boilers powered by KOR, covering models 1007-4007.
Factory-Supplied Flow Switch Replacement Kit and Shipped-Loose, Field-Installation Kit
242042
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
These instructions cover the replacement of the factory-installed Flow Switch and provide guidance for installing a "shipped-loose" Flow Switch in the field for XVers boilers powered by KOR, covering models 1007-4007.
Blower Replacement Kit and Blower Gasket Replacement Kit
242044
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
These instructions cover the replacement of both the Blower and Blower Gasket for XVers boilers powered by KOR, covering models 1007-4007.
D-33 Polypropylene Vent Adapter Kit
242046
1005A, 1505A, 2005A
XTherm Heating Boilers, Models 1005A-2005A
Boilers & Water Heaters
This manual provides instructions for the replacement of the D-33 Vent Adapter Kit on XTherm Boilers, specifically models 1005A-2005A.
Drain Shield Installation Kit
242047
88AR, 108AR, 198AR, 278AR, 398A
XPak FT Boiler, Type H, Models 88AR-398A
Boilers & Water Heaters
This manual provides instructions for installing the drain shield assembly on XPak FT boilers, specifically models 88AR through 398A.
Modulation Gas-Blower/Valve Assembly Kit
242063
88A, 108A
XPak FT Wall Hung Heating Boiler, Models 88A & 108A
Boilers & Water Heaters
This manual provides instructions for the replacement of the blower/valve assembly on XPak FT models 88A and 108A.
CSD-1 Field Upgrade Kit 016677 High and Low Gas Pressure Switches
242064
0856, 1006, 1256, 1506, 1756, 2006, 2506, 3006
XVers Heating Boiler Models 856-3006
Boilers & Water Heaters
This kit enables a field upgrade to CSD-1 standards, incorporating High and Low Gas Pressure Switches for Raypak Commercial Boilers of the XVers series, specifically Models 856-3006.
Vertical SureRack™ Assembly Instructions
100-10000358
300B, 400B, 500B, 650B, 800B, 1000B
XFIIRE Models: Boiler/Water Heater: 300B to 1000B, IFire Models: Boiler/Water Heater: IBGWSF1 0300 to 1000
Boilers & Water Heaters
This manual provides instructions for the assembly of the vertical SureRack™ for XFiire and IFire boiler/water heater models ranging from 300 to 1000.
XVers (Powered by KOR) Heating Boilers Models 1007-4007
Boilers & Water Heaters
These instructions provide details for field-installing the HO2T monitoring hardware for XVers (powered by KOR) boilers.
Install Burner Ground Wire Kit
100-10000810
406L, 506L, 606L, 726L, 856L
XVers L Condensing Fire-Tube Boiler Models 406L-856L
Boilers & Water Heaters
These instructions detail the installation process for the burner and low voltage ground wire on XVers L boilers.
Shutoff Valve and Nipple Replacement for Raytherm Heaters
100-10000912
1758, 1826, 2100, 2500
1758-2500
Boilers & Water Heaters
This document provides instructions for replacing the gas train's Shutoff Valve and Nipple in Raytherm heaters, models 1758 through 2500.
Replacement Instructions of the Gas Train's Ball Valve and Nipple
100-10000928
2503, 3003, 3503, 4003, 2505, 3005, 3505, 4005
MVB Sizes: 2503-4003 (Natural Gas and Propane), XTherm Sizes: 2505-4005 (Propane and Natural Gas)
Boilers & Water Heaters
This document provides instructions for replacing the gas train's Ball Valve and Nipple in MVB and XTherm Raypak Commercial Appliances, ensuring proper operation and safety compliance.
Details the procedure and components necessary for descaling the heater tubes to maintain efficiency and operation.
Commercial Drafthood Installation Instructions
240569
186 RC, 264 RC, 183B, 263B
186 RC, 264 RC, 183B, 263B
Pool & Spa / Boilers & Water Heaters
Provides detailed steps for installing a drafthood on commercial gas appliances, including the necessary tools and conversion instructions from outdoor to indoor setups
Gas Valve Replacement for IID Boilers Instructions
Guide on replacing two-stage gas valves for boilers with standing pilot systems, including detailed installation and wiring instructions
Gas Valve Replacement for IID Units Instructions
240575
514, 624, 724, 516, 602
514-724, 516, & 602
Pool & Spa / Boilers & Water Heaters
Detailed instructions for replacing gas valves in intermittent ignition device units, including steps for handling various models and checking system integrity post-installation
Gas Train Conversion Kit Instructions
240577
105A
105A
Pool & Spa / Boilers & Water Heaters
Instructions for converting gas trains from Natural Gas to Propane and vice versa, including detailed steps for replacing orifices and regulators
Booster Burner Tray
240584
B-130
B-130
Pool & Spa / Boilers & Water Heaters
Booster Burner Tray Replacement Instructions
Booster Heat Exchanger Installation Guide
240585
B-130
B-130
Pool & Spa / Boilers & Water Heaters
Guide for field installation of a heat exchanger in gas booster heaters, including step-by-step installation procedures and safety tips
Booster Tube Bundle Installation Guide
240586
B-130
B-130
Pool & Spa / Boilers & Water Heaters
Instructions for the field installation of the tube bundle for gas booster heaters, including preparation, removal, and installation steps
Booster Pump Installation Instructions
240587
B-195
B-195
Pool & Spa / Boilers & Water Heaters
Guide for installing pumps in booster heaters, detailing the kit contents, and providing step-by-step installation instructions
Hot Surface Ignitor Replacement Guide
240588
B-50, B-130, B-130A, B-195
B-50, B-130, B-130A, B-195
Pool & Spa / Boilers & Water Heaters
Provides instructions for replacing the hot surface ignitor in various booster heater models, including safety precautions and installation steps
Booster Refractory Installation Guide
240589
B-130
B-130
Pool & Spa / Boilers & Water Heaters
Instructions for installing refractory blocks in booster heaters, detailing the removal and installation process
Booster Flue Collector Replacement Instructions
240590
B-195
B-195
Pool & Spa / Boilers & Water Heaters
Guide for replacing the flue collector in booster heaters, including detailed procedures for disassembly and reassembly
Hi Delta Models 302-2342, 302A-2342A, 302B-2342B, 302C-2342C, and Delta Ltd. Models 399-2339, 399B-2339B
Pool & Spa / Boilers & Water Heaters
Installation guide for the SureRack Kit and X-3 Restraint Kit, specifically designed for Hi Delta and Delta Ltd. models.
CHX High Temp Limit Installation Instructions
241010
CHX Models using PVC or CPVC venting
Pool & Spa / Boilers & Water Heaters
Instructions for installing the CHX High Temp Limit, a manual reset temperature switch designed specifically for CHX models vented with PVC or CPVC materials. This safety device is critical as it automatically shuts off the heater if the flue temperature exceeds the safe operating limits of the vent materials.
Instructions for field installation of the Raypak IFS01-BN-S2 Flow Switch kit, which is a direct replacement for the OEM flow switch. This kit is applicable for all Raypak appliances equipped with a flow switch, except the HPPH.
These installation instructions cover the addition of a flow switch and temperature/pressure gauge for specified atmospheric and low NOx pool heater models.
Instructions for the installation of the E-5 alarm with a 4-inch alarm bell and silencing assembly, applicable for MVB and X-Therm models.
Motorized Sealed Damper Installation Instructions
241461
1505A, 2005A
H, WH, WHP 1505-2005
Pool & Spa / Boilers & Water Heaters
This kit includes all the necessary components for the field installation of a motorized, sealed damper in the exhaust system of a CAT IV vented appliance with an 8" flue collar.
CSD-1 Field Upgrade Kit PIM Controller & Low/High Pressure Gas Switches
This document outlines the steps for installing low and high pressure gas switches and the single-try Platform Ignition Module (PIM) on various Raypak commercial appliances.
This kit facilitates the field installation of the Raypak D-37 Combustion Air Damper across multiple model ranges. Each model is equipped with the VERSA IC Controller, ensuring compatibility and functionality with the damper system for efficient operation.
Provides installation instructions for Raymote service components within the MVB and XVers models, as well as XTherm units. These instructions detail how to integrate Raymote services effectively with these systems.
Provides installation instructions for Raymote service components within the MVB and XVers models, as well as XTherm units. These instructions detail how to integrate Raymote services effectively with these systems.
Condensing Boilers, Water Heaters, and Pool Heaters
Pool & Spa / Boilers & Water Heaters
This manual provides instructions for installing Raypak's Z-12 Condensate Neutralization kits, suitable for condensing boilers, water heaters, and pool heaters.
Heat Pump Control Board Replacement Kit
241889
Applicable to various heat pump models, especially those with earlier non-digital boards
Pool & Spa / Boilers & Water Heaters
This kit provides all necessary components to replace the control board or any non-digital board previously used in older heat pump models. The kit ensures updated functionality and compatibility with current system operations.
VERSA IC® Board and SD Card Updates for Cascade Expansion
XVers, MVB, XTherm, and Hi Delta with Touchscreens
Pool & Spa / Boilers & Water Heaters
This manual details the process for replacing the VERSA IC® board and updating the SD cards to enhance the touchscreen functionality on applicable models.
Service LOW NOX Adjustment XVERS KOR
100-10002893
1007, 1257, 1507, 2007, 2507, 3007, 3507, 4007
XVERS KOR
Boilers & Water Heaters
Allows customers to fine tune boiler for low nox reading
INSTALL HIGH TENSION WIRE IFIIRE
100-10003884
300B, 400B, 500B, 650B, 800B, 1000B
XFIIRE
Boilers & Water Heaters
Allows customers to install high tension wire.
Winterizing AVIA Heater
100-10003933
AVIA, 264, 404, 264A, 404A
AVIA
Pool & Spa
Provide instructions for draining the AVIA heater of water (winterizing) in preparation for non-use during the colder months.